Room Temperature Tensile Properties of Bar as a Function of Diameter and Percentage Cold-work
Bar Diameter*
|
Cold-work
|
Room Temperature Tensile Properties
|
0.2% Offset Yield Strength
|
Ultimate Tensile Strength
|
Elongation
|
in
|
mm
|
%
|
ksi
|
MPa
|
ksi
|
MPa
|
%
|
0.5
|
12.7
|
43
|
191.1
|
1317
|
196.5
|
1355
|
18.2
|
0.75
|
19.1
|
44
|
204.7
|
1411
|
210.0
|
1448
|
15.5
|
1.0
|
25.4 |
44
|
188.3
|
1298
|
193.8
|
1336
|
17.6
|
1.25
|
31.8
|
46
|
205.2
|
1415
|
210.9
|
1454
|
15.4 |
1.567
|
39.8 |
37
|
184.2
|
1270
|
192.7
|
1329
|
17.4
|
2.0
|
50.8
|
47
|
207.5
|
1431
|
212.0
|
1462
|
13.0
|
2.375
|
60.3
|
54
|
181.4
|
1251
|
190.5
|
1313
|
21.2
|
2.5
|
63.5
|
49
|
180.0
|
1241
|
183.7
|
1267
|
18.2
|
3.62
|
91.9
|
42
|
192.3
|
1326
|
197.3
|
1360
|
14.0 |
*Averages from duplicate test samples
Room and Elevated Temperature Tensile Properties of Cold-worked Tube
(3.5 in Diameter by 0.43 in Wall Thickness) (52-53%) as a Function of Orientation
(Longitudinal and Transverse)
Test Temperature
|
Orientation
|
0.2% Offset Yield Strength
|
Ultimate Tensile Strength
|
Elongation
|
Reduction of Area
|
°F
|
°C
|
ksi
|
MPa
|
ksi
|
MPa
|
%
|
%
|
RT
|
RT
|
Longitudinal
|
166.0
|
1145
|
180.4
|
1244
|
18.8
|
69.5
|
Transverse
|
156.3
|
1078
|
175.8
|
1212
|
29.2
|
63.6
|
400
|
204
|
Longitudinal
|
149.3
|
1029
|
157.6
|
1087
|
16.8
|
68.7
|
Transverse
|
143.2
|
987
|
155.1
|
1069
|
25.8
|
64.8
|
500
|
260
|
Longitudinal
|
147.6
|
1018
|
154.2
|
1063
|
16.5
|
67.1
|
Transverse
|
138.0 |
951
|
151.4
|
1044
|
24.8
|
60.9
|
600
|
316
|
Longitudinal
|
144.9
|
999
|
151.5
|
1045
|
16.9
|
66.4
|
Transverse
|
135.7
|
936
|
147.5
|
1017
|
25.5
|
62.3 |
Values are averages from 10 tests
RT= Room Temperature